OmsaStorageMonitor
The OmsaStorageMonitor lets you monitor your Dell OpenManaged servers RAID array status. This monitor supports the following OIDs from the STORAGEMANAGEMENT-MIB:
virtualDiskRollUpStatus .1.3.6.1.4.1.674.10893.1.20.140.1.1.19
arrayDiskLogicalConnectionVirtualDiskNumber .1.3.6.1.4.1.674.10893.1.20.140.3.1.5
arrayDiskNexusID .1.3.6.1.4.1.674.10893.1.20.130.4.1.26
arrayDiskLogicalConnectionArrayDiskNumber .1.3.6.1.4.1.674.10893.1.20.140.3.1.3
arrayDiskState .1.3.6.1.4.1.674.10893.1.20.130.4.1.4
The virtualDiskRollUpStatus value checks the status of the disk array. If the result of the virtualDiskRollUpStatus is not 3, the monitor is marked as down.
Result | State description | Monitor state in Horizon |
---|---|---|
1 |
other |
DOWN |
2 |
unknown |
DOWN |
3 |
ok |
UP |
4 |
non-critical |
DOWN |
5 |
critical |
DOWN |
6 |
non-recoverable |
DOWN |
You need to know the maximum number of possible logical disks you have in your environment. For example, if you have three RAID arrays, you need a service poller for each logical disk array. |
To give more detailed information in case of a disk array error, the monitor tries to identify the problem using the other OIDs. These values enrich the error reason in the service down event. The disk array state is resolved to a human-readable value as in the following status table.
Value | Status |
---|---|
1 |
Ready |
2 |
Failed |
3 |
Online |
4 |
Offline |
6 |
Degraded |
7 |
Recovering |
11 |
Removed |
15 |
Resynching |
24 |
Rebuilding |
25 |
noMedia |
26 |
Formatting |
28 |
Running Diagnostics |
35 |
Initializing |
Configuration and use
Parameter | Description | Default |
---|---|---|
virtualDiskNumber |
The disk index of your RAID array. |
1 |
port |
The TCP port where OpenManage listens. |
From snmp-config.xml |
This monitor implements the Common Configuration Parameters.
Examples
Sample configuration on how to configure the monitor in poller-configuration.xml
.
Note that you must include the monitor
section in your definition.
The RAID array monitor for your first array is configured with virtualDiskNumber = 1
and may look like this:
<service name="OMSA-Disk-Array-1" interval="300000" user-defined="false" status="on">
<parameter key="retry" value="3"/>
<parameter key="timeout" value="6000"/>
<parameter key="virtualDiskNumber" value="1"/>
</service>
<monitor service="OMSA-Disk-Array-1" class-name="org.opennms.netmgt.poller.monitors.OmsaStorageMonitor"/>
If there is more than one RAID array to monitor, you need an additional configuration.
In this case, virtualDiskNumber = 2
.
<service name="OMSA-Disk-Array-2" interval="300000" user-defined="false" status="on">
<parameter key="retry" value="3"/>
<parameter key="timeout" value="6000"/>
<parameter key="virtualDiskNumber" value="2"/>
</service>
<monitor service="OMSA-Disk-Array-2" class-name="org.opennms.netmgt.poller.monitors.OmsaStorageMonitor"/>